TROUBLE & ERROR CODES
AR-C150, AR-C160, AR-C250, AR-C270)
A0 0 ROM trouble (PCU MAIN PWB) PCU MAIN PWB When POWER ON Power
OFF/ON
C1 10 Main charger trouble (BLACK) Image process Warm-up /
Initialize
Power
Source-ON
C1 11 Main charger trouble (CYAN) Image process Warm-up /
Initialize
Power
Source-ON
C1 12 Main charger trouble (MAGENTA) Image process Warm-up /
Initialize
Power
Source-ON
C1 13 Main charger trouble (YELLOW) Image process Warm-up /
Initialize
Power
Source-ON
EE EL Toner concentration reference control
level setup trouble (Overtoner)
Image process
(Developing)
SIM 25-2 Power
Source-ON
EE EU Toner concentration reference control
level setup trouble (Undertoner)
Image process
(Developing)
SIM 25-2 Power
source-ON
E7 10 Shading trouble (Black correction) Scanner (reading)
/ICU SCAN PWB
Warm-up /
Initialize
Power
source-ON
E7 11 Shading trouble (White correction) Scanner (reading)
/ICU SCAN PWB
Warm-up /
Initialize
Power
source-ON
E7 20 Laser beam sensor trouble (BLACK) Scanner (writing) All modes Power
source-ON
E7 21 Laser beam sensor trouble (CYAN) Scanner (writing) All modes Power
source-ON
E7 22 Laser beam sensor trouble
(MAGENTA)
Scanner (writing) All modes Power
source-ON
E7 23 Laser beam sensor trouble (YELLOW) Scanner (writing) All modes Power
source-ON
E7 24 Laser beam detection trouble (BLACK) Scanner (writing) All modes Power
source-ON
E7 25 Laser beam detection trouble (CYAN) Scanner (writing) All modes Power
source-ON
E7 26 (Laser beam detection trouble
(MAGENTA)
Scanner (writing) All modes Power
source-ON
E7 27 Laser beam detection trouble
(YELLOW)
Scanner (writing) All modes Power
source-ON
E7 30 ICU PWB FLASH ROM trouble ICU MAIN PWB Warm-up /
Initialize
Power
source-ON
E7 90 ICU MAIN PWB -PCU MAIN PWB
communication trouble (PCU side
detection)
ICU MAIN PWB /
PCU MAIN PWB
All modes Power
source-ON
E8 0 ICU MAIN PWB -PCU MAIN PWB
communication trouble (PCU side
detection)
ICU MAIN PWB /
PCU MAIN PWB
All modes Power
source-ON
E8 1 ICU MAIN PWB -PCU MAIN PWB
communication trouble (PCU side
detection)
ICU MAIN PWB /
PCU MAIN PWB
All modes Power
source-ON
F1 0 Communication trouble between PCU
MAIN PWB -Finisher control PWB
(Detected by PCU MAIN PWB)
PCU MAIN PWB /
Finisher control
PWB
When power ON /
initial operation
Power
OFF/ON
F1 2 Finisher paper exit trouble (Finisher
side detection)
Finisher paper exit When power ON /
initial operation
Power
OFF/ON
F1 10 Finisher staple trouble (Finisher side
detection)
Finisher stapler When stapling Power
OFF/ON
F1 11 Finisher bundle process trouble
(Finisher side detection)
Finisher paper exit When power ON /
initial operation
Power
OFF/ON
F1 15 Finisher tray lift trouble (Finisher side
detection)
Finisher tray lift All modes Power
OFF/ON
F1 19 Finisher alignment trouble (Front side)
(Finisher side detection)
Finisher alignment When POWER ON Power
OFF/ON
F1 20 Finisher alignment trouble (Rear side)
(Finisher side detection)
Finisher alignment When POWER ON Power
OFF/ON
F1 70 PCU PWB -sorter control PWB
communication trouble (PCU detection)
Sorter / PCU MAIN
PWB
Warm-up /
Initialize
Power
source-ON
10 –2A
Main
code
Sub
code
Title (Content) Section Operation mode Remedy NOTE
F1 80 Sorter power abnormality (Sorter side
detection)
Sorter All modes Power
source-ON
F1 81 Sorter transport motor trouble (Sorter
side detection)
Sorter Sort/group
operation mode
Power
source-ON
F1 83 Sorter push bar motor trouble (Sorter
side detection)
Sorter Initializing Power
source-ON
F1 87 Sorter staple unit oscillation motor
trouble (Sorter side detection)
Sorter Initializing Power
source-ON
F1 89 Sorter bin shift motor trouble (Sorter
side detection)
Sorter Sort / Group
operation mode
Power
source-ON
F1 91 Bin paper sensor auto adjustment
trouble (Sorter side detection)
Sorter Sort/group
operation mode
Power
source-ON
F1 94 Sorter staple key trouble Sorter Staple Power
source-ON
F2 40 Toner concentration sensor trouble
(BLACK)
Developing All modes Power
source-ON
F2 41 Toner concentration sensor trouble
(CYAN)
Developing All modes Power
source-ON
F2 42 Toner concentration sensor trouble
(MAGENTA)
Developing All modes Power
source-ON
F2 43 Toner concentration sensor trouble
(YELLOW)
Developing All modes Power
source-ON
F2 44 Image density sensor trouble (BLACK)
(Transfer belt surface reflection
abnormality)
Image process
(Transfer)
Image density
correction
Power
source-ON
Print is disabled in USA/Japan. For the
other destinations, print is enabled.
However, the print density must be
forcibly decreased.
F2 45 Image density sensor trouble
(COLOR) (Calibration plate reflection
abnormality)
Image process
(Transfer)
Image density
correction
Power
source-ON
Print is disabled in USA/Japan. For the
other destinations, print is enabled.
However, the print density must be
forcibly decreased.
F2 50 Drum marking detection trouble
(BLACK)
Image process
(OPC drum)
OPC drum rotation Power
source-ON
In the case of AR-C100, the error code
is displayed (print disabled). In the
case of AR-C150/C250/C160/C270,
the error code is stored in the trouble
memory (print enabled).
F2 51 Drum marking detection trouble
(CYAN)
Image process
(OPC drum)
OPC drum rotation Power
source-ON
In the case of AR-C100, the error code
is displayed (print disabled). In the
case of AR-C150/C250/C160/C270,
the error code is stored in the trouble
memory (print enabled).
F2 52 Drum marking detection trouble
(MAGENTA)
Image process
(OPC drum)
OPC drum rotation Power
source-ON
In the case of AR-C100, the error code
is displayed (print disabled). In the
case of AR-C150/C250/C160/C270,
the error code is stored in the trouble
memory (print enabled).
F2 53 Drum marking detection trouble
(YELLOW)
Image process
(OPC drum)
OPC drum rotation Power
source-ON
In the case of AR-C100, the error code
is displayed (print disabled). In the
case of AR-C150/C250/C160/C270,
the error code is stored in the trouble
memory (print enabled).
F2 54 Drum marking sensor gain adjustment
error (BLACK)
Image process
(OPC drum)
Image density
correction
Power
source-ON
Print is disabled in USA/Japan. For the
other destinations, print is enabled.
However, the print density must be
forcibly decreased.
F2 55 Drum marking sensor gain adjustment
error (CYAN)
Image process
(OPC drum)
Image density
correction
Power
source-ON
Print is disabled in USA/Japan. For the
other destinations, print is enabled.
However, the print density must be
forcibly decreased.
F2 56 Drum marking sensor gain adjustment
error (MAGENTA)
Image process
(OPC drum)
Image density
correction
Power
source-ON
Print is disabled in USA/Japan. For the
other destinations, print is enabled.
However, the print density must be
forcibly decreased.
F2 57 Drum marking sensor gain adjustment
error (YELLOW)
Image process
(OPC drum)
Image density
correction
Power
source-ON
Print is disabled in USA/Japan. For the
other destinations, print is enabled.
However, the print density must be
forcibly decreased.
10 – 3A
Main
code
Sub
code
Title (Content) Section Operation mode Remedy NOTE
F2 58 Process humidity sensor trouble Image process
(Transfer)
All modes Power
source-ON
In the case of AR-C100, the error code
is displayed (print disabled). In the
case of AR-C150/C250/C160/C270,
the error code is stored in the trouble
memory (print enabled).
F2 63 Temperature sensor trouble (Image
process)
Image process All modes Power
source-ON
In the case of AR-C100, the error code
is displayed (print disabled). In the
case of AR-C150/C250/C160/C270,
the error code is stored in the trouble
memory (print enabled).
F2 80 Half tone correction (1st patch) trouble
(BLACK)
Image process Image density
correction
Power
source-ON
F2 81 Half tone correction (1st patch) trouble
(CYAN)
Image process Image density
correction
Power
source-ON
F2 82 Half tone correction (1st patch) trouble
(MAGENTA)
Image process Image density
correction
Power
source-ON
F2 83 Half tone correction (1st patch) trouble
(YELLOW)
Image process Image density
correction
Power
source-ON
F2 84 Half tone correction (2nd patch)
trouble (BLACK)
Image process Image density
correction
Power
source-ON
F2 85 Half tone correction (2nd) patch
trouble (CYAN)
Image process Image density
correction
Power
source-ON
F2 86 Half tone correction (2nd) patch
trouble (MAGENTA)
Image process Image density
correction
Power
source-ON
F2 87 Half tone correction (2nd) patch
trouble (YELLOW)
Image process Image density
correction
Power
source-ON
F2 90 Half tone correction trouble Image process Image density
correction
Power
source-ON
F3 12 Lift-up trouble (Paper 1) Paper tray 1 Paper tray lift up Power
source-ON
F3 22 Lift-up trouble (Paper 2) Paper tray 2 Paper tray lift up Power
source-ON
F3 32 Lift-up trouble (Paper 3) Paper tray 3 Paper tray lift up Power
source-ON
F3 42 Lift-up trouble (Paper 4) Paper tray 4 Paper tray lift up Power
source-ON
F9 0 ICU PWB-printer controller
communication trouble (ICU detection)
ICU IMAGE PWB /
PRINTER
CONTROLLER
Warm-up / Printing Power
source-ON
H2 0 Fusing main temperature sensor
(lower)(Thermistor) open/Fusing unit
not-installed (THS1)
Fusing All modes Power
Source-ON
H2 1 Fusing main temperature sensor
(lower)(Thermistor) open/Fusing unit
not-installed (THS2)
Fusing All modes Power
Source-ON
H2 2 Fusing main temperature sensor
(upper)(Thermistor) open/Fusing unit
not-installed (THS3)
Fusing All modes Power
Source-ON
H2 3 Fusing main temperature sensor
(upper)(Thermistor) open/Fusing unit
not-installed (THS4)
Fusing All modes Power
Source-ON
H3 0 Fusing section high temperature
trouble (THS1)
Fusing All modes SIM 14
H3 1 Fusing section high temperature
trouble (THS2)
Fusing All modes SIM 14
H3 2 Fusing section high temperature
trouble (THS3)
Fusing All modes SIM 14
H3 3 Fusing section high temperature
trouble (THS4)
Fusing All modes SIM 14
H4 0 Fusing section (upper) low
temperature trouble (HL1)
Fusing All modes SIM 14
H4 1 Fusing section (lower) low temperature
trouble (HL2)
Fusing All modes SIM 14
H5 1 Paper jam in the fusing/paper exit
sections
Fusing Copy / Print SIM 14
10 – 4A
Main
code
Sub
code
Title (Content) Section Operation mode Remedy NOTE
H6 0 Fusing oil empty (Oil sensor trouble) Fusing All modes Power
Source-ON
H7 0 AC input voltage (HLV) trouble Power source All modes Power
Source-ON
L1 0 Scanner feed trouble Scanner (reading) Initialize / Copy Power
Source-ON
L3 0 Scanner return trouble Scanner (reading) Initialize / Copy Power
Source-ON
L4 3 Fusing motor trouble Fusing Warm-up / Copy/
Print
Power
Source-ON
L4 4 Developing motor trouble (BLACK) Developing drive Warm-up / Copy/
Print
Power
Source-ON
L4 5 Developing motor trouble (COLOR) Developing drive Warm-up / Copy /
Print
Power
Source-ON
L4 6 Transfer belt lift trouble Image process
(Transfer)
Color /
Monochrome copy
(print) mode select
Power
Source-ON
L6 10 Laser scanner (writing) motor lock
detection (BLACK)
Laser scanner
(writing)
All modes Power
Source-ON
L6 11 Laser scanner (writing) motor lock
detection (CYAN)
Laser scanner
(writing)
All modes Power
Source-ON
L6 12 Laser scanner (writing) motor lock
detection (MAGENTA)
Laser scanner
(writing)
All modes Power
Source-ON
L6 13 Laser scanner (writing) motor lock
detection (YELLOW)
Laser scanner
(writing)
All modes Power
Source-ON
L8 1 Power full wave signal (FWS) trouble Power source All modes Power
Source-ON
L8 2 Power full wave signal (FWS) width
trouble
Power source All modes Power
Source-ON
PF 0 RIC copy inhibit signal reception PCU PWB RIC
communication
SIM 17
U0 0 Operation control PWB - PCU MAIN
PWB communication trouble
(OPE/PCU detection)
Operation
PWB/PCU MAIN
PWB
All modes Power
Source-ON
U0 80 PCU MAIN PWB - PCUSUB PWB
communication trouble (PCU detection)
PCU SUB
PWB/PCU MAIN
PWB
All modes Power
Source-ON
U2 0 EEPROM read/write error (PCU MAIN
PWB)
PCU PWB Warm-up SIM 16
U2 11 Counter data (EEPROM) check sum
error (PCU MAIN PWB)
PCU PWB All modes SIM 16
U2 12 Setup/Adjustment value data
(EEPROM) check sum error (PCU
MAIN PWB)
PCU PWB All modes SIM 16
U2 20 EEPROM read/write error (ICU MAIN
PWB)
ICU PWB Warm-up SIM 16
U2 21 Counter (EEPROM) check sum error
(ICU MAIN PWB)
ICU PWB All modes SIM 16
U2 22 Setup, adjustment value (EEPROM)
check sum error (ICU MAIN PWB)
ICU PWB All modes SIM 16
U2 30 Manufacturing No. data (ICU MAIN
PWB/PCU MAIN PWB) discrepancy
ICU PWB / PCU
PWB
All modes SIM 16
U4 0 PCU MAIN PWB -ADU
communication trouble
PCU PWB / Duplex
control PWB
Warm-up /
Initialize
Power
Source-ON
U4 2 ADU Alignment plate operation trouble Duplex Initialize/Duplex
copy (print)
Power
Source-ON
U4 12 ADU transport motor trouble Duplex Duplex copy (print) Power
Source-ON
U5 0 PCU MAIN PWB - RADF
communication trouble
PCU PWB / RADF
control PWB
Warm-up /
Initialize
Power
Source-ON
U5 1 RADF resist sensor trouble RADF RADF Power
Source-ON
U5 2 RADF expulsion sensor trouble RADF RADF Power
Source-ON
10 – 5A
Main
code
Sub
code
Title (Content) Section Operation mode Remedy NOTE
U5 3 RADF timing sensor trouble RADF RADF Power
Source-ON
U5 11 RADF paper feed motor trouble RADF RADF Power
Source-ON
U6 9 Large capacity tray (LCC) lift motor
trouble
Large capacity tray Paper feed SIM 15
U6 20 PCU MAIN PWB-Large capacity tray
(LCC) communication trouble
Large capacity tray
control PWB / PCU
MAIN PWB
Warm-up /
Initialize
Power
Source-ON
U6 21 Large capacity tray (LCC) transport
motor trouble
Large capacity tray Paper feed Power
Source-ON
U6 22 Large capacity tray (LCC) 24v power
trouble
Large capacity tray All modes Power
Source-ON
U7 0 RIC communication trouble PCU PWB RIC
communication
Power
Source-ON
UC 0 ICU SCAN PWB -CPT PWB
communication trouble
ICU SCAN PWB /
CPT PWB
Copy Power
Source-ON
UC 1 CPT board program trouble CPT PWB Warm-up /
Initialize
Power
Source-ON
UC 2 CPT board ASIC trouble CPT PWB Warm-up /
Initialize
Power
Source-ON
UC 3 CPT board ROM trouble CPT PWB Warm-up /
Initialize
Power
Source-ON
UC 4 CPT board RAM trouble CPT PWB Warm-up /
Initialize
Power
Source-ON
UC 5 CPT board model code data trouble ICU MAIN PWB /
CPT PWB
Warm-up /
Initialize
Power
Source-ON
6. Details
Main
code
Sub
code
Title Shading trouble (White correction)
Phenomena Display Lamp E7 11
Message
Detail In shading correction, the CCD white reading level is abnormal (with the scanner lamp OFF).
Section Scanner (reading) / ICU SCAN PWB
Operation mode Warm-up / Initialize
Note
Case 1 Trouble
position/Cause
Improper CCD white level gain
Too great CCD white level gain
Remedy (Check)
1) Use SIM 63-1 to check the values of ADJUST ODD GAIN and ADJUST EVEN GAIN of each color
of R/G/B. (There are six values in total.) (AR-C150)
2) Add 25 to each value of GAIN ODD and GAIN EVEN of R/G/B checked in procedure 1) and make
notes of the total values. (AR-C150)
3) Enter the SIM 46-6 mode, and replace each value of GAIN ODD and GAIN EVEN of R/G/B with
the total values calculated in procedure 2). (Input the new value.) (AR-C150)
4) Cancel the simulation.
5) Turn OFF/ON the power, and shading operation will be performed.
(Repair) Power OFF-ON
(After work)
Note This trouble occasionally happens when the CCD unit (with the lens) is replaced.
Case 2 Trouble
position/cause
Bad connection of the flat cable between the CCD unit and the ICU SCAN PWB.
Remedy (Check) Check connection of the flat cable between the CCD unit and the ICU SCAN PWB.
(Repair) Replace the flat cable between the CCD unit and the ICU SCAN PWB. / Power Source-ON
(After-work)
Note
10 – 6A
Main
Sub
Title
code
code
E7
Case 3
11
Case 4
Case 5
Case 6
Shading trouble (White correction)
CCD unit trouble
(Check) CCD black offset level check (SIM 46-6) / Shading correction result check (SIM 63-1)
(AR-C150 only)
(Repair) Replace the CCD unit. / Power Source-ON
(After-work) Adjust ADJM17-ADJ1.
ICU SCAN PWB, ICU IMAGE PWB, ICU MAIN PWB trouble
(Check)
(Repair) ICU SCAN PWB, ICU IMAGE PWB, ICU MAIN PWB. / Power Source-ON
(After-work) Adjust ADJM9/M10/M12/M13/M14/M15/M17. / Re-enter setup values and adjustment
values. (Install the EEPROM of the defective ICU MAIN PWB to a new ICU MAIN PWB.)
Scanner section dirt (Shading sheet trouble (dirt, scratch)/Lens dirt/Mirror dirt/Reflector dirt)
(Check) Scanner section dirt check
(Repair) Clean the scanner section (shading sheet/lens/CCD/mirror/reflector)./Power Source-ON
(After-work)
Scanner lamp insufficient light quantity (Scanner lamp trouble/scanner lamp control PWB trouble)
(Check) Check the scanner lamp applying voltage (62.3V).
(Repair) Replace the scanner lamp. / Replace the scanner lamp control PWB. / Power Source-ON
(After-work) Adjust ADJM17-ADJ1.
Trouble
position/cause
Remedy
Note
Trouble
position/cause
Remedy
Note
Trouble
position/cause
Remedy
Note
Trouble
position/cause
Remedy
Note
Main
Sub
Title
code
code
F1
Phenomenon
2
Case 1
Case 2
Case 3
Finisher paper exit trouble/reversing trouble (Finisher side detection)
Lamp
Message
Detail In the initial operation, the motor rotation sensor output signal is not recognized within the specified
time after output of the finisher paper exit motor / reversing motor ON signal.
Section Finisher paper exit
Operation mode Power ON/ Initial operation
Paper exit motor trouble / Reversing motor trouble / Paper exit motor rotation sensor trouble /
Reversing motor rotation sensor trouble
(Check) Check the paper exit motor / reversing motor / Reversing motor rotation sensor / paper exit
motor rotation sensor operations. (SIM 3-1/2)
(Repair) Replace the paper exit motor. / Replace the paper exit motor rotation sensor. / Power
OFF-ON
(After work)
Paper exit mechanism section trouble
(Check) Check the paper exit mechanism section operation. (SIM 3-1/2)
(Repair) Replace or repair parts of the paper exit mechanism section. / Power OFF-ON
(After work)
Finisher control PWB trouble
(Check) Check the finisher control PWB operation. (SIM 3-1/2)
(Repair) Replace the finisher control PWB. / Power OFF-ON
(After work) Make various adjustments related to the finisher electric section. (Install the EEPROM
of the defective finisher control PWB to a new finisher control PWB.)
Display
NOTE
Trouble position /
Cause
Remedy
Trouble position /
Cause
Remedy
Trouble position /
Cause
Remedy
10 – 7A
Main
code
Sub
code
Title Fusing motor trouble
L4 3 Phenomena Display Lamp
Message
Detail The motor lock signal is detected for 50ms or more during rotation of the fusing motor.
Section Paper feed
Operation mode Paper feed
Note
Case 1 Trouble
position/cause
Fusing motor trouble
Remedy (Check) Check the fusing motor operation. (SIM 6-1)
(Repair) Replace the fusing motor. / Power Source-ON
(After-work)
Note
Case 2 Trouble
position/cause
PCU MAIN PWB trouble
Remedy (Check)
(Repair) Replace the PCU MAIN PWB. / Power Source-ON
(After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU
MAIN PWB to a new PCU MAIN PWB.)
Note
Case 3 Trouble
position/cause
Fusing mechanism section trouble.
Remedy (Check) Check the loads in the fusing mechanism section.
(Repair) Repair or replace parts in the fusing mechanism section. / Power Source-ON
(After-work)
Note
Main
code
Sub
code
Title Developing motor trouble (BLACK)
L4 4 Phenomena Display Lamp
Message
Detail The motor lock signal is detected for 3.5sec or more when the developing motor is ON.
Section Developing drive
Operation mode Warm-up / Copy / Print
Note
Case 1 Trouble
position/cause
Developing motor trouble
Remedy (Check) Check the developing motor operation (SIM 25-1).
(Repair) Replace the developing motor. / Power Source-ON
(After-work)
Note
Case 2 Trouble
position/cause
Developing mechanism section trouble
Remedy (Check) Check the loads of the developing mechanism section.
(Repair) Repair or replace the parts in the developing mechanism section. / Power Source-ON
(After-work)
Note
Case 3 Trouble
position/cause
PCU MAIN PWB trouble
Remedy (Check)
(Repair) Replace the PCU MAIN PWB. / Power Source-ON
(After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU
MAIN PWB to a new PCU MAIN PWB.)
Note
10 – 8A
Main
Sub
Title
Developing motor trouble (COLOR)
code
code
Phenomena
Display
Lamp
L4
5
Message
Detail
The motor lock signal is detected for 3.5sec or more when the developing motor is ON.
Section
Developing drive
Operation mode
Warm-up / Copy / Print
Note
Case 1
Trouble
Developing motor trouble
position/cause
Remedy
(Check) Check the developing motor operation (SIM 25-1).
(Repair) Replace the developing motor. / Power Source-ON
(After-work)
Note
Case 2
Trouble
Developing mechanism section trouble
position/cause
Remedy
(Check) Check the loads of the developing mechanism section.
(Repair) Repair or replace the parts in the developing mechanism section. / Power Source-ON
(After-work)
Note
Case 3
Trouble
PCU MAIN PWB trouble
position/cause
Remedy
(Check)
(Repair) Replace the PCU MAIN PWB. / Power Source-ON
(After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU
MAIN PWB to a new PCU MAIN PWB.)
Note
Case 4
Trouble
Developing motor power line trouble
position/cause
Remedy
(Check) Check the fuse (F707).
(Repair) Replace the fuse (F707). / Power Source-ON
(After-work)
Note
Main
Sub
Title
PCU MAIN PWB ADU communication trouble / Discrepancy of the model
code
code
Phenomena
Display
Lamp
U4
0
Message
Detail
Communication test error in warm-up / Discrepancy of the model
Section
PCU PWB / Duplex control PWB
Operation mode
Warm-up / Initialize
Note
Case 1
Trouble
Bad connection of the signal line between the PCU MAIN PWB and the ADU control PWB.
position/cause
Remedy
(Check) Check connection of the signal line between the PCU MAIN PWB and the ADU control PWB.
(Repair) Repair or replace the cable and the connector between the PCU MAIN PWB and the ADU
control PWB. / Power Source-ON
(After-work)
Note
Case 2
Trouble
PCU MAIN PWB trouble
position/cause
Remedy
(Check)
(Repair) Replace the PCU MAIN PWB. / Power Source-ON
(After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU
MAIN PWB to a new PCU MAIN PWB.)
Note
Case 3
Trouble
ADU control PWB trouble
position/cause
Remedy
(Check)
(Repair) ADU control PWB replacement / Power Source-ON
(After-work)
Note
Case 4
Trouble
Discrepancy of the model code (The AR-DU2, instead of the AR-DU2N, is erroneously installed to the
position/cause
AR-C160/C270.).
Remedy
(Check) Check that the AR-DU2N or the AR-DU2 is installed.
(Repair) Install the AR-DU2N or remodel the AR-DU2 into the AR-DU2N. (Replace the AR-DU2 ROM
with the AR-DU2N ROM, and replace the 1A fuse on the ADU control PWB with the 1.25A fuse.)
(After-work)
Note
10 – 9A
Main
code
Sub
code
Title
PCU MAIN PWB- Large capacity tray (LCC) communication trouble /
Discrepancy of the model
Phenomena Display Lamp U6 20 Message
Detail Communication test error in warm-up / Discrepancy of the model
Section Large capacity tray control PWB / PCU MAIN PWB
Operation mode Warm-up / Initialize
Note
Case 1 Trouble
position/cause
Bad connection of the signal line between the PCU MAIN PWB and the large capacity tray (LCC)
control PWB
Remedy (Check) Check connection of the signal line between the PCU MAIN PWB and the large capacity tray
(LCC) control PWB.
(Repair) Repair or replace the cable and the connector between the PCU MAIN PWB and the large
capacity tray (LCC) control PWB. / Power Source-ON
(After-work)
Note
Case 2 Trouble
position/cause
PCU MAIN PWB trouble
Remedy (Check)
(Repair) Replace the PCU MAIN PWB. / Power Source-ON
(After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU
MAIN PWB to a new PCU MAIN PWB.)
Note
Case 3 Trouble
position/cause
Large capacity tray (LCC) control PWB trouble
Remedy (Check)
(Repair) Large capacity tray (LCC) control PWB replacement / Power Source-ON
(After-work)
Note
Case 4 Trouble
position/cause
Discrepancy of the model code (The AR-LC2, instead of the AR-LC2N, is erroneously installed to the
AR-C160/C270.).
Remedy (Check) Check that the AR-LC2N or the AR-LC2 is installed.
(Repair) Install the AR-LC2N or remodel the AR-LC2 into the AR-LC2N. (Replace the AR-LC2 ROM
with the AR-LC2N ROM, and replace the 1A fuse on the ADU control PWB with the 1.25A fuse.)
(After-work)
Note
10 – 10A
Home
Kode Error SHARP
Subscribe to:
Posts
(
Atom
)
thanks info nya gan, kebetulan lagi menangani troble ac h3
ReplyDeletesalam kenal dari depok